all types of Incubators

Microplate Reader

Product Specifications

It is controlled by computer to complete Enzyme Linked Immunosorbent Assay (ELISA). Read 48 welland 96 well microplate, analyse and report, which are widely used in clinical diagnostic laboratories,centers for disease control and prevention, animal and plant quarantine, animal husbandry and veterinaryepidemic prevention stations, biotechnological industries, food industries, environmental science,agricultural scientific research and other academic organizations. MICROPLATEREADER

Technical Specifications

Light Source :

6V, 10W tungsten halogen lamp, it can work over 5000hours

Wavelength
Range :

400~750nm

Optical Filters :

4 standard filters:405,450,492, 630nm, maximum8filters

Measurement
Methods :

single wavelength, dual wavelength, two points method, dynamic assay, multiple wavelengths

Blank Ways :

single well blank, multiple wells blank, rows and columns blank

Calculation
Method :

absorbance, single point calibration, linear regression, quadratic curve, four parameters equation

Measurement
Speed :

single wavelength < 3 seconds/96 wells, dual wavelength <9 seconds/96wells

Measurement
Range :

0.0000-4.5000Abs

Resolution :

0.0001A

Linearity :

± 0.5% or<0.025 A

Repeatability
Difference :

< 0.1%or±0.0025A

Rows and
Columns
Difference :

< 0.01A

Display :

built-in XP system, 8″ touch-screen, shows whole microplate results and calibration curve

Save
Information :

more than 300 test programs, results of 50 pieces of 96 well,100000testresults

Interface :

4 USB two-way communication interface, 1 RS232, 1VGA,1Keyboardconnector, 1mouse connector

Environment :

power supply 12V DC (100V-240V wide input voltagerange);temperature:5°C-40°C

External
Dimension :

52.5cm(20.7in) × 42.0cm(16.5in)×26.0cm(10.20in)

Net Weight :

9kg

Microplate Washer

Product Specifications

PW-812 controlled by mircrocomputer to wash 48 well and 96 well microplate in experiments of ELISA, Time-Resolved immunofluorometric Assay, (TRFIA) and Chemiluminescence, which are widely used in clinical diagnostic laboratiories, centers for disease control and prevention, animal and plant quarantine, animal husbandry and veterinary edidemic prewention stations, biotechnologial industrial industries, food industries, environmental science, agriculture

Technical Specifications

Plate Models :

96\48 well plate or strip(Flat U & V – bottom)

Wash Head :

8 or 12 Head Manifold

Wash Mode :

Plate & Row

Wash Rows :

1-12 or 1-8 rows

User Interface :

5″ LCD Display

Wash
Programs :

100 User entered wash protocols

Strip Washing :

1 to 12 Strips Programmable

Washing Cycle :

Up to 99 cycles

Dispensing
Volume :

50~950µL for8-12 way manifold

Dispensing
Precision :

< 1.5 % at 350 µl

Aspiration
Time :

0.1 – 9.9 Seconds

Prime Volume :

50 – 1000 µl

Aspiration
Pressure :

Adjustable pump Pressure

Soak Time :

0∼999 seconds or minutes

Shaking Time :

0∼999 seconds or minutes

Residual
Volume :

≤ 0.7 ∼ 1 µl/well

Rinse Pipeline
Time :

1 ∼ 240 Sec adjustable, bottom washing & two point aspirating function.

Auto DW Wash :

0-20 Plate Auto Distilled Water wash

Number of
Bottles :

2 Wash buffer, 1 Rinse/DI & Waste bottle with sensor (2L each)

Power Supply :

AC 110/220V, 50-60HZ / 50VA

Operating
Temperature :

10 C – 30 C

Storage
Temperature :

10 C – 40 C

Relative
Humidity :

Up to 90% relative humidity without condensation

Atmospheric
Pressure :

86 Kpa ∼ 106 Kpa

Weight :

09 kg